Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. bras. anestesiol ; 65(3): 163-169, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-748920

ABSTRACT

INTRODUCTION: The use of ultrasound in regional anesthesia allows reducing the dose of local anesthetic used for peripheral nerve block. The present study was performed to determine the minimum effective concentration (MEC90) of bupivacaine for axillary brachial plexus block. METHODS: Patients undergoing hand surgery were recruited. To estimate the MEC90, a sequential up-down biased coin method of allocation was used. The bupivacaine dose was 5 mL for each nerve (radial, ulnar, median, and musculocutaneous). The initial concentration was 0.35%. This concentration was changed by 0.05% depending on the previous block; a blockade failure resulted in increased concentration for the next patient; in case of success, the next patient could receive or reduction (0.1 probability) or the same concentration (0.9 probability). Surgical anesthesia was defined as driving force ≤2 according to the modified Bromage scale, lack of thermal sensitivity and response to pinprick. Postoperative analgesia was assessed in the recovery room with numeric pain scale and the amount of drugs used within 4 h after the blockade. RESULTS: MEC90 was 0.241% [R 2: 0.978, confidence interval: 0.20-0.34%]. No patient, with successful block, reported pain after 4 h. CONCLUSION: This study demonstrated that ultrasound guided axillary brachial plexus block can be performed with the use of low concentration of local anesthetics, increasing the safety of the procedure. Further studies should be conducted to assess blockade duration at low concentrations. .


INTRODUÇÃO: O uso do ultrassom na anestesia regional permite a redução da dose de anestésico local utilizada para o bloqueio de nervos periféricos. O presente estudo foi conduzido com o objetivo de determinar a concentração mínima efetiva (CME90) de bupivacaína para o bloqueio do plexo braquial via axilar (BPVA). MÉTODOS: Pacientes submetidos a cirurgias da mão foram recrutados. Foi usado um método de alocação "biased coin" seqüencial "up-down" para estimar a CME90. A dose de bupivacaína foi de 5 mL para cada nervo (radial, ulnar, mediano e musculocutâneo). A concentração inicial de era 0,35%. Essa concentração era alterada em 0,05% dependendo do bloqueio anterior: a falha do bloqueio resultava em aumento da concentração para o próximo paciente; no caso de sucesso, o próximo paciente poderia receber ou redução (probabilidade de 0,1) ou mesma concentração (probabilidade 0,9). A anestesia cirúrgica foi definida como força motora ≤ 2 segundo a escala de Bromage modificada, ausência de sensibilidade térmica e de resposta ao pinprick. A analgesia pós-operatória foi verificada na sala de recuperação anestésica com escala numérica de dor e a quantidade de analgésicos utilizados até 4 horas após o bloqueio. RESULTADOS: A CME90 foi de 0,241% [R2: 0,978, Intervalo de Confiança: 0,20%-0,34%]. Além disso, nenhum paciente com sucesso do bloqueio apresentou dor após 4 horas. CONCLUSÃO: Este estudo demonstrou que pode-se realizar o BPVA guiado por ultrassom utilizando-se baixas concentrações de anestésico local, aumentando a segurança do procedimento. Novos estudos devem ser realizados para avaliar a duração de bloqueios com baixas concentrações. .


INTRODUCCIÓN: El uso de la ecografía en la anestesia regional permite la reducción de la dosis de anestésico local utilizada para el bloqueo de nervios periféricos. El presente estudio fue llevado a cabo con el objetivo de determinar la concentración mínima efectiva (CME90) de bupivacaína para el bloqueo del plexo braquial vía axilar. MÉTODOS: Fueron reclutados pacientes sometidos a cirugías de la mano. Se usó un método de ubicación "biased coin" secuencial "up-down" para estimar la CME90. La dosis de bupivacaína fue de 5 mL para cada nervio (radial, cubital, mediano y musculocutáneo). La concentración inicial era de un 0,35%. Esa concentración era alterada en un 0,05% dependiendo del bloqueo anterior: El fallo del bloqueo revertía en un aumento de la concentración al próximo paciente; en caso de éxito, el próximo paciente podría recibir o una reducción (probabilidad de 0,1) o la misma concentración (probabilidad 0,9). La anestesia quirúrgica fue definida como fuerza motora ≤ 2 según la escala de Bromage modificada, ausencia de sensibilidad térmica y de respuesta al pinprick (test del pinchazo de la aguja). La analgesia postoperatoria fue verificada en la sala de recuperación anestésica con la escala numérica de dolor y la cantidad de analgésicos utilizados hasta 4 h después del bloqueo. RESULTADOS: La CME90 fue del 0,241% [R2: 0,978, intervalo de confianza: 0,20-0,34%]. Además, ningún paciente con éxito en el bloqueo tuvo dolor después de 4 h. CONCLUSIÓN: Este estudio demostró que se puede realizar el bloqueo del plexo braquial vía axilar guiado por ecografía utilizando bajas concentraciones de anestésico local, aumentando la seguridad del procedimiento. Nuevos estudios deben ser realizados para calcular la duración de bloqueos con bajas concentraciones. .


Subject(s)
Humans , Male , Female , Adult , Bupivacaine/administration & dosage , Ultrasonography, Interventional/methods , Brachial Plexus Block/methods , Anesthetics, Local/administration & dosage , Pain, Postoperative/prevention & control , Pain Measurement , Dose-Response Relationship, Drug , Hand/surgery
2.
Rev. bras. anestesiol ; 64(1): 49-53, Jan-Feb/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-704240

ABSTRACT

Justificativa e objetivo: o uso do ultrassom para acompanhar o correto posicionamento da agulha e a dispersão do anestésico local permitiu a redução do volume de anestésico local necessário para o bloqueio de nervos periféricos. Existem poucos trabalhos sobre o volume mínimo efetivo de anestésico local para o bloqueio do plexo braquial via axilar (BPVA). Este estudo foi conduzido com o objetivo de determinar o volume mínimo efetivo (VE90) de bupivacaína 0,5% comadrenalina (1:200.000) para o BPVA guiado por ultrassom. Método: o método up-and-down proposto por Massey e Dixon foi usado para o cálculo do volume mínimo efetivo. A dose inicial foi de 5 ml por nervo (radial, mediano, ulnar e musculocutâneo). No caso de falha do bloqueio, o volume era aumentado em 0,5 mL por nervo. O sucesso do bloqueio resultava na diminuição do volume em 0,5 mL por nervo para o paciente subsequente. O sucesso do bloqueio foi definido como bloqueio da função motora ≤ 2 segundo a escala de Bromage modificada, ausência de sensibilidade térmica e de resposta ao pinprick. Foi definido como critério para término do estudo a obtenção de cinco casos de falha seguidos de casos de sucesso. Resultados: foram incluídos 19 pacientes no estudo. O volume mínimo efetivo (VE90) de bupi-vacaína 0,5% com 1:200.000 de adrenalina foi de 1,56 ml (IC 95% 0,99-3,5) por nervo. Conclusão: este trabalho corrobora alguns estudos que mostram que é possível obter anestesia cirúrgica com baixos volumes de anestésico local para bloqueios de nervo periférico guiados por ultrassom. .


Background and objective: The use of ultrasound for needle correct placement and local anesthetic spread monitoring helped to reduce the volume of local anesthetic required for peripheral nerve blocks. There are few studies of the minimum effective volume of local anesthetic for axillary brachial plexus block. The aim of this study was to determine the minimum effective volume (VE90) of 0.5% bupivacaine with epinephrine (1:200,000) for ultrasound guided ABPB. Method: Massey and Dixon's up-and-down method was used to calculate the minimum effective volume. The initial dose was 5 mL per nerve (radial, median, ulnar, and musculocutaneous). In case of blockade failure, the volume was increased to 0.5 mL per nerve. A successful blockade resulted in decreased volume of 0.5 mL per nerve to the next patient. Successful blockade was defined as a motor block ≤2, according to the modified Bromage scale; lack of thermal sensitivity; and response to pinprick. The achievement of five cases of failure followed by success cases was defined as criterion to complete the study. Results: 19 patients were included in the study. The minimum effective volume (VE90) of 0.5% bupivacaine with 1:200,000 epinephrine was 1.56 mL (95% CI, 0.99-3.5) per nerve. Conclusion: This study is in agreement with some other studies, which show that it is possible to achieve surgical anesthesia with low volumes of local anesthetic for ultrasound-guided peripheral nerve blocks. .


Justificación y objetivo: el uso del ultrasonido para acompanar el correcto posicionamiento de la aguja y la dispersión del anestésico local ha permitido la reducción del volumen de anestésico local necesario para el bloqueo de los nervios periféricos. Existen pocos trabajos sobre el volumen mínimo efectivo de anestésico local para el bloqueo del plexo braquial vía axilar. Este estudio fue llevado a cabo con el objetivo de determinar el volumen mínimo efectivo (VE90) de bupivacaína al 0,5% con adrenalina (1:200.000) para el bloqueo del plexo braquial vía axilar guiado por ultrasonido. Método: el método up-and-down propuesto por Massey y Dixon fue usado para el cálculo del volumen mínimo efectivo. La dosis inicial fue de 5mL por nervio (radial, mediano, cubital y musculocutáneo). En el caso de fallo en el bloqueo, el volumen se aumentaba a 0,5 mL por nervio. El éxito del bloqueo traía la disminución del volumen en 0,5 mL por nervio para el paciente posterior. El éxito del bloqueo se definió como bloqueo de la función motora < 2 según la escala de Bromage modificada, ausencia de sensibilidad térmica y de respuesta al pinprick. Quedó definido como criterio para el término del estudio la obtención de 5 casos de fallo seguidos de casos de éxito. Resultado: se incluyeron 19 pacientes en el estudio. El volumen mínimo efectivo (VE90) de bupivacaína al 0,5% con 1:200.000 de adrenalina fue de 1,56 mL (IC 95%: 0,99-3,5) por nervio. Conclusiones: este trabajo corrobora algunos estudios que muestran que se puede obtener la anestesia quirúrgica con bajos volúmenes de anestésico local para bloqueos de nervio periférico guiados por ultrasonido. .


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Anesthetics, Local/administration & dosage , Brachial Plexus Block/methods , Bupivacaine/administration & dosage , Ultrasonography, Interventional
SELECTION OF CITATIONS
SEARCH DETAIL